Energy Requirement

The energy requirement of soap drying depends on the kind of drying process and the drying degree of the final product.

Vacuum driers need cooling water for condensation of withdrawn water and steam in case of higher cooling water temperatures, for vapor compression needed then.

When using the vapor extraction patented by SELA, the motive steam being required for operation of the steam ejector is not necessary. Then the steam ejector is operated with the vapor being separated from the soap, as already described in section "vapor extraction". For condensation of the vapor quantity in the condenser cooling water is required.

Atmospheric plants require cooling water for the chill roll. Heating steam is needed as well for the heat exchangers of the drying system and the smoothing roll of the chill roll. For operation of the plodder and the chill roll electrical energy and cooling water are required.

Indications of following tables are standard values for usual conditions and do not represent any guarantee values.

Toilet soap

Vacuum Drying Plants
max.
cooling
water
temp.
°C
Direct condensation with vapor compression
and non-circulation cooling
without
vapor extraction
with
vapor extraction
steam
kgs/hr
water
m³/hr
steam
kgs/hr
water
m³/hr
18 410 15 285 12
22 430 19 285 14
26 460 24 285 18
30 510 30 285 22
34 570 36 285 26
max.
cooling
water
temp.
°C
Surface condensation
with circulation cooling
without
vapor extraction
with
vapor extraction
steam
kgs/hr
water
m³/hr
steam
kgs/hr
water
m³/hr
18 410 35 285 26
22 430 40 285 28
26 460 45 285 31
30 510 52 285 33
34 570 60 285 38
Atmospheric Drying Plants
max.
cooling
water
temp.
°C
non-circulating
cooling
circulation
cooling
water
m³/hr
el. power
kW
15 8 -
- - 25

Laundry soap

Vacuum Drying Plants
max.
cooling
water
temp.
°C
Direct condensation with vapor compression
and non-circulation cooling
without
vapor extraction
steam
kgs/hr
water
m³/hr
18 195 15,5
22 245 17
26 275 22,5
30 295 30
34 310 37
max.
cooling
water
temp.
°C
Surface condensation
with circulation cooling
without
vapor extraction
steam
kgs/hr
water
m³/hr
18 195 36
22 245 38
26 275 45
30 295 50
34 310 63
Atmospheric Drying Plants
max.
cooling
water
temp.
°C
non-circulating
cooling
circulation
cooling
water
m³/h
el. power
kW
- - 30

The steam and water consumption is based on a steam feeding pressure of 9 bars abs. The water consumption is based on continuous requirement.