Atmospheric Drying Plants

Flowsheet of a two stage atmospheric drier for toilet soap
Flowsheet of a two stage atmospheric drier for toilet soap

SELA driers with atmospheric expansion are built in series in single-stage or two-stage construction for 1000 up to 6000 kgs of soap/hr according to the evaporation capacity. Soap feeding pumps and heat exchangers have the same characteristics as described in the champter Vacuum Drier.

In case of two-stage plants the evaporation capacity of every stage is nearly the same.

Chill roll
Chill roll

If necessary, the expansion chambers have a stirring device in order to guarantee an uniform discharge. A ventilator is installed for exhausting the steam resulting from drying.

Level control can be made through a sight glass and corresponding lighting. An electrical level control is possible at choice.

The soap is cooled down by contact cooling on a cooling roll with layer thicknesses below one millimeter.

Tubular heat exchanger
Tubular heat exchanger

About 8 to 10 m3 water/1000 kgs soap with cooling water temperatures of maximum 15°C are required for cooling. Cooling by means of cold water circuits with re-cooling via refrigerating machine is possible at choice.

The chips taken off the cooling roll are supplied with a conveyor worm to a plodder and compressed to noodles.

News

ACHEMA 2012

30th World Exhibition Congress . Frankfurt am Main . 18 - 22 June 2012